Prefabricated nursery buildings for early years and childcare providers: this L-shaped KC Bespoke model combines a 12.60m × 6.30m wing with a 9.45m × 12.60m wing, providing 198.45m² of gross external floor area. The supplied package includes internal partition panels, SPC flooring, triple-glazed laminated windows, sanitary-area fittings and finishes, heat-pump heating and cooling, plus mainland UK delivery and on-site assembly.
- Model / system
- L-Shaped Nursery / KC Bespoke
- Wing A
- 12.60m × 6.30m / 79.38m² gross
- Wing B
- 9.45m × 12.60m / 119.07m² gross
- Total gross external area
- 198.45m²
- Nursery layout
- Activity and support rooms to the agreed two-wing floor plan
- Delivery & assembly
- Included within mainland UK
- Programme
- Confirmed with the order
Mainland UK delivery and on-site modular assembly are included in the stated £353,245 + VAT price. Agree the delivery route, vehicle access, lifting arrangements, positions of both wings and foundation readiness before installation. Groundworks, foundations, external nursery works and final mains connections are separate unless expressly included in writing.
Buy the stated building specification or agree adaptations before ordering. The two wings are building sections, not an asserted module count or fixed room schedule. Child places, usable areas, sanitary quantities and services are confirmed on approved drawings. Furniture and external play works shown in the visualisation are not included unless itemised.
Available to order
KC Bespoke | L-shaped nursery & early years accommodation
Prefabricated nursery buildings with two connected wings
Create a larger early years setting with this 198.45m² L-shaped nursery building. Two connected wings provide a starting point for separate activity areas, quiet or rest spaces and shared support rooms, with the internal arrangement developed around the nursery brief and site.
The footprint comprises a 12.60m × 6.30m section and a 9.45m × 12.60m section. Their respective gross external areas are 79.38m² and 119.07m², giving the stated total of 198.45m². These are two adjoining, non-overlapping building sections; the final plan defines their orientation and connecting junction.
The L-shaped arrangement can be planned to separate age groups or activities while coordinating shared toilets, changing facilities, storage, staff space and reception. The internal corner, routes between rooms and outdoor entrances require specific supervision and circulation planning; the shape alone does not guarantee visibility or safeguarding.
This model uses the same supplied technical specification as the KC Bespoke V-Design nursery: an insulated steel frame, Kingspan panel systems, triple glazing with laminated safety glass, SPC flooring, FD30 doorsets, scheduled sanitary finishes and heat-pump heating and cooling. It is a larger fitted building specification, not a shell-and-core offer.
For providers comparing prefabricated nursery buildings, the stated £353,245 + VAT price includes mainland UK delivery and on-site modular assembly. Foundations, final mains connections, outdoor play works and equipment outside the agreed fit-out remain separate.
The visualisation shows a contemporary glazed L-shaped nursery with light cladding and dark frames beside a landscaped outdoor area. It is an illustration of the intended setting, not a measured floor plan or a completed-project reference. Final glazing positions, entrances, roof levels and finishes follow the approved elevations.
Compare the 79.38m² V-Design nursery building, browse our nursery and early years buildings, or download the KC Bespoke Collection catalogue (PDF). This L-shaped product's agreed specification and drawings define the purchased building.
- Wing A footprint
- 12.60m × 6.30m
- Wing B footprint
- 9.45m × 12.60m
- Total gross external floor area
- 198.45m²
- Layout
- L-shaped / two connected wings
- Specified wall / roof / floor U-values
- 0.18 / 0.11 / 0.11 W/m²K
- Delivery & assembly
- Mainland UK included
Applications and layout options
Independent childcare providers
L-Shaped Nursery Building
Develop activity and support rooms across two connected wings. The layout can distinguish younger-child, preschool or quiet activities according to the brief, without assuming a fixed number of rooms or child places.
Schools and academy trusts
Modular Nursery Building for Schools
Provide dedicated school-based nursery accommodation with an agreed relationship to existing entrances, secure boundaries and outdoor areas. Any physical connection to another building is separately designed and scheduled.
Day nursery operators
Prefabricated Nursery Buildings for Expansion
Plan additional space for play, learning, rest, hygiene, storage and staff needs within the 198.45m² gross footprint. Qualifying activity areas are measured only after the room schedule and circulation are resolved.
Preschool and early years provision
Early Years Buildings with Shared Facilities
The connected-wing layout can coordinate shared sanitary and support facilities with separate activity spaces. Fixture quantities, access arrangements and the outdoor interface are confirmed before manufacture.
Indicative product specification
Use this table as a configuration guide. The written quotation and approved drawings control the final product, interfaces and project-specific compliance.
| Product line | KC Bespoke; the same supplied technical package as the V-Design nursery, not ISO Frame or shell and core |
|---|---|
| Model | L-Shaped Prefabricated Nursery Building |
| Wing A | 12.60m × 6.30m / 79.38m² gross external area |
| Wing B | 9.45m × 12.60m / 119.07m² gross external area |
| Total gross external area | 198.45m² from the two non-overlapping wing areas; not net usable childcare activity space |
| Overall site envelope | Final L-shaped orientation, outside dimensions and setbacks to the approved site and floor plans |
| Storeys | Single-storey L-shaped design shown |
| Module division | Two wings do not mean two transport modules. Final module count, orientation and junctions to approved drawings |
| Internal height | Confirmed on project sections; no numerical clear height has been supplied |
| Room schedule and occupancy | Confirmed against age groups, usable area, support facilities and provider requirements |
| Wing allocation | Allocate activity, quiet or rest and support spaces to the two wings through an approved room schedule |
|---|---|
| Connected circulation | Coordinate doorways and routes at the internal return so movement between wings does not rely on unplanned through-routes in activity rooms |
| Staff visibility | Review sightlines around the internal corner and between activity, rest and outdoor access points |
| Arrival and safeguarding | Agree parent arrival, controlled access and staff reception; no door count or access-control equipment is inferred from the image |
| Toilets and changing | Agree child and adult facilities, nappy changing, handwashing and storage; quantities and fitting heights follow the final schedule |
| Outdoor connection | The space beside the two wings can be planned with the nursery outdoor area. Secure boundaries, surfacing and equipment require separate design and allocation |
| Accessibility | Review approach routes, thresholds, clear door widths and circulation through both wings as one connected building |
| Plan status | The supplied external visualisation is not a dimensioned layout or evidence of a fixed room arrangement |
| Area basis | Child-place assessment uses qualifying usable activity-room space, not the 198.45m² gross external floor area |
|---|---|
| Children under two | EYFS indoor space reference: 3.5m² per child |
| Two-year-olds | EYFS indoor space reference: 2.5m² per child |
| Children aged three to five | EYFS indoor space reference: 2.3m² per child |
| Excluded from qualifying area | Storage, through-routes, dedicated staff areas, cloakrooms, utility rooms, kitchens and toilets |
| Capacity conclusion | No child capacity is assigned without an approved measured layout, staffing arrangements and provider review |
| Source and jurisdiction | EYFS statutory framework for group and school-based providers in England; use the framework applicable to the provider and opening date. Other UK nations have their own requirements. |
| Structural connection | Design the connected wing junctions, support reactions and module fixings for the approved layout |
|---|---|
| Roof interfaces | Coordinate wing roof levels, falls, outlets and membrane junctions; the illustration does not establish finished heights or drainage falls |
| Envelope continuity | Detail insulation, weather seals and movement joints at module and wing connections |
| Services across wings | Coordinate electrical, water, drainage, heating and ventilation routes with the room and equipment schedules |
| Fire and evacuation | Review escape routes, doors, detection and compartmentation for the full L-shaped layout; no fixed exit count is asserted |
| Design basis | The component material specification is retained from V-Design; structural calculations and service sizing must be developed for this larger building |
| Primary frame | High-strength closed steel profiles |
|---|---|
| Protection | Anti-corrosive coating to structural steel |
| Construction format | Factory-manufactured modular steel-frame building |
| Engineering | Member sizes, module connections, support reactions and lifting details to project-specific structural design |
| External wall panel | Kingspan KS1000/1150 TL panels or an approved equivalent |
|---|---|
| Specified U-value | 0.18 W/m²K |
| Reaction-to-fire reference | EN 13501-1 B-s2,d0 as supplied; verify the classification for the selected panel |
| Fire-resistance references | EW 45 (o↔i), stated 4m span; EI 30 (o↔i), stated 7.5m span, as provided in the technical brief |
| Acoustic reference | 25 (-3,-5) dB as supplied for the panel; not a room-to-room or whole-nursery acoustic rating |
| Installation | Vertical or horizontal where supported by the exact selected system and its fixing details |
| Optional core alternative | Mineral-wool core may be separately specified; it is not the default QuadCore core |
| Evidence | Panel thickness, span, orientation, fixings and junctions must match supporting manufacturer documentation |
| Partition panels | Kingspan QuadCore KS1150TL, 100mm |
|---|---|
| Panel finish | Double-sided white finish |
| Layout | Partitions to the agreed nursery floor plan; movable partitions are not specified |
| Internal fire doors | FD30 doorsets to the approved fire and opening schedule |
| Smoke control | Smoke-control seals and compatible hardware specified as part of the complete doorset where required |
| Nursery acoustic design | Room acoustics and sound separation require a layout-specific assessment; additional acoustic treatments must be scheduled |
| Child safety hardware | Finger protection, closers, restrictors and controlled opening arrangements to the final safety and ironmongery schedule |
| Insulated assembly | 160mm Kingspan QuadCore KS1150TL specified within the roof build-up |
|---|---|
| Specified roof U-value | 0.11 W/m²K |
| Roof membrane | Protan SE 2.0 |
| Membrane detailing | Welded seams, UV resistance and product fire performance to the membrane specification |
| Roof design | Panel suitability, support, substrate, falls, outlets and membrane compatibility must be confirmed for the complete assembly |
| Solar option | Solar equipment is not included; any later installation requires a structural, fixing and roof-compatibility review |
| Structure | Insulated steel floor system |
|---|---|
| Specified floor U-value | 0.11 W/m²K for the complete floor build-up |
| Structural deck | 18mm cement-bonded chipboard |
| Finished flooring | SPC rigid-core vinyl |
| Use classification | Class 42 as specified |
| Appearance | Wood or stone texture selected from the agreed range |
| Water resistance | Waterproof SPC product; joints, edges and wet areas must be detailed to the selected installation system |
| Nursery suitability | Confirm slip performance, thresholds, cleaning regime and wet-play requirements for the selected floor product; no specific slip or impact-cushioning rating is claimed |
| Window frames | Multi-chamber UPVC |
|---|---|
| Window glazing | Triple glazing with laminated safety glass |
| Specified window U-value | 0.9 W/m²K |
| Entrance doors | Aluminium entrance doors with RAL colour selection and high-security locking |
| Specified door U-value | 1.1 W/m²K |
| Feature elevation | L-shaped architectural treatment and glazing positions to approved elevations; no angled V-Design openings are assumed |
| Child-safety coordination | Agree impact-safe glazing, manifestation, restrictors, guarding where needed and safe operating heights |
| Daylight and summer comfort | Review orientation, solar gain, glare, shading and ventilation; large areas of glass alone do not establish comfort |
| Opening schedule | Exact dimensions, quantities, positions and the laminated-glass specification to the final schedule |
| Sanitary system | GEBERIT wall-hung toilets to the agreed sanitary schedule |
|---|---|
| Storage | Quality under-sink cabinets |
| Wall panels | Rocko Tiles, 2800 × 1230 × 4mm in vertical format |
| Wet-area finish | Waterproof, easy-clean finishes with joints and penetrations detailed for the selected system |
| Nursery-specific schedule | Confirm child-height fittings, adult facilities, nappy-changing provision and handwashing points before order sign-off |
| Water and drainage | Internal routing, hot-water provision, temperature control and external service interfaces to the agreed mechanical specification |
| Included climate control | Air-to-air heat pump for heating and cooling |
|---|---|
| Specified SCOP | 4.5, subject to the selected equipment and declared operating conditions |
| System selection | Heating and cooling capacity, zones, indoor-unit position and noise criteria coordinated with occupancy and room use |
| Ventilation | Fresh-air supply and wet-area extraction must be designed separately; an air-to-air heat pump is not a fresh-air ventilation system |
| Electrical and lighting schedule | Confirm circuits, sockets, lighting, emergency lighting, detection, alarms, data and access-control scope in the written order |
| Hot water and food preparation | Confirm equipment and capacity for handwashing, changing and any food-preparation activity; no kitchen appliance package is stated |
| Cladding | Hidden-fix steel elevation panels |
|---|---|
| Substrate | Hot-dip galvanised steel |
| Standard RAL range | 1015, 3000, 3009, 3011, 5010, 6029, 7016, 7024, 7035, 8004, 8017, 9002, 9006, 9007 and 9010 |
| Other standard finish | Galvanised |
| Colour pricing | No surcharge for the listed standard steel cladding and flashing finishes |
| Final appearance | Agree colours, cassette layout, roof-edge details and both wing elevations from drawings and samples; image colours are not verified RAL codes |
| Wood-effect options | Golden Oak, Dark Walnut and Winchester; premium upgrade |
|---|---|
| Brick-slip options | Nicea 1 / Nicea; Boston 1 / Boston with joint; Bronx Red 1 on request / Bronx Red with joint; Cambridge 13 / Cambridge; Country 610 / Country; Dallas 1 / Dallas with joint; Dublin 3 / Dublin with joint; Monsanto 1 / Monsanto with joint; Rustik 540 / Rustik |
| Decorative-stone options | Alzano; Amsterdam; Calabria 1 / Calabria; California; Grenada 1 / Grenada; Jura 1 / Jura; Kenya 1 / Kenya; Lyon 1 / Lyon; Madera 2 / Madera; Mexicana 3 / Mexicana; Nepal; Palermo; Roma 1 / Roma; Sierra; Timber 1 / Timber; Toledo 2 / Toledo |
| Joint treatment | Jointed or unjointed where available for the selected product |
| Commercial status | Separately priced upgrades, not automatic additions to this nursery specification |
| Suitability | Select exterior-rated variants and confirm support, attachment, fire performance, weather exposure, movement joints and coverage before manufacture |
| Certification ownership | Manufacturer certifications and manufacturing-system approvals relate to the actual production organisation and scope, not to KC Cabins Solutions Ltd unless KC is expressly identified as the holder |
|---|---|
| Technical evidence | Supporting calculations, material declarations and test reports must match the final components and assembled building |
| Part L | The supplied brief references Part L 2021. Confirm the applicable edition and transitional arrangements for the actual project; do not assume that the 2021 label applies to every new order |
| Optional A energy rating | An A-rating can be a separately assessed design objective; no issued EPC or universal A-rating is claimed for this listing |
| Fire strategy | Panel classifications, element fire-resistance data and FD30 doorsets do not establish a 60-minute whole-building fire rating |
| Nursery registration | Buying a building does not register a childcare provider or constitute Ofsted approval. Confirm the provider-specific requirements before opening |
| Official guidance | Approved Document L — England and Building Regulations approval guidance support the project review; other UK jurisdictions use different guidance. |
| Delivery | Included within mainland UK in the stated price |
|---|---|
| On-site modular assembly | Included in the stated price |
| Logistics | Agree vehicle routing, access, lifting methodology, site segregation and module positions before delivery |
| Occupied nursery or school | Plan secure separation of works, controlled vehicle movements and installation timing with the setting |
| Groundworks and mains connections | Separate unless expressly included in writing |
| Programme | Manufacturing, delivery, assembly and commissioning dates confirmed after the design and site review |
| Handover | Final commissioning, safety checks and the agreed handover records must be completed before occupation; no opening date is promised from the product image |
Scope, responsibilities and assumptions
Included in the stated prefabricated nursery building specification
- 198.45m² L-shaped KC Bespoke nursery: 12.60m × 6.30m wing plus 9.45m × 12.60m wing
- Steel structural frame with anti-corrosive protection
- External insulated panels with specified wall U-value 0.18 W/m²K
- 100mm Kingspan QuadCore KS1150TL internal partitions to the agreed layout
- 160mm insulated roof assembly with Protan SE 2.0 membrane
- Insulated steel floor and 18mm cement-bonded chipboard deck
- SPC rigid-core vinyl floor finish, specified Class 42
- Triple-glazed UPVC windows with laminated safety glass
- Aluminium entrance doors and FD30 internal doorsets to the approved schedule
- GEBERIT sanitary fittings, under-sink storage and Rocko Tiles finishes to the agreed sanitary schedule
- Air-to-air heat-pump heating and cooling with specified SCOP 4.5
- Hidden-fix steel cladding and flashings in a listed standard finish
- L-shaped building configuration and façade treatment to approved drawings
- Delivery within mainland UK
- On-site modular assembly
Separate site, nursery equipment and optional scope
- Groundworks, excavations, foundations and supporting base unless expressly included
- Incoming power, water, foul drainage, surface-water drainage and final mains connections
- Planning, statutory application fees and childcare registration responsibilities unless the order allocates professional services otherwise
- External fencing, gates, paths, access ramps, decking, play surfacing, play equipment and landscaping unless listed
- Loose furniture, toys, educational resources, cots, specialist changing equipment and storage not identified in the fit-out schedule
- Kitchen appliances and specialist food-preparation equipment unless expressly specified
- Optional wood-effect, brick-slip and decorative-stone façade upgrades
- Additional specialist acoustic treatments, security equipment or solar installation unless included in the agreed schedule
Design and order confirmations
- The nursery brief identifies age groups, target places, opening hours and staffing arrangements
- A measured floor plan identifies qualifying activity areas separately from toilets, circulation and support rooms
- The plan treats the supplied wings as adjoining non-overlapping sections; overall orientation, junctions and service distribution are approved before manufacture
- The final room, sanitary, electrical, lighting, ventilation, alarm and hot-water schedules are agreed before manufacture
- Plant capacity, room quantities, sanitary provision and opening schedule are designed for the 198.45m² building rather than copied as fixed quantities from the smaller V-Design model
- Safeguarding, access, glazing, acoustics, fire strategy and outdoor interfaces are reviewed for the particular site
- The prepared foundations, access route, lifting arrangements and utility capacities are suitable for the building
- The stated specification and included mainland UK delivery and assembly are retained unless a written variation is agreed
- Changes in layout, specialist equipment or upgraded finishes are agreed commercially before production
The listed price is for the stated building specification with mainland UK delivery and assembly, not an entire equipped nursery business or a completed external play scheme. The signed order and approved schedules define the final layout, service scope and project responsibilities.
How the project progresses
- Define your early years brief Confirm the postcode, age groups, target places, operating model, staff needs, budget and target opening date.
- Plan the nursery layout Develop measured activity areas, quiet or rest spaces, toilets, changing, storage and staff facilities across the two wings. Resolve supervision, routes around the internal corner and movement to outdoor areas.
- Approve the scope and evidence Agree the floor plan, wing connections, elevations, service schedules, material selections, regulatory route and the priced building scope before the agreed payment and manufacturing stage.
- Manufacture and prepare the site Factory work and separately allocated foundations and utility preparation proceed to the coordinated programme.
- Deliver, assemble and hand over Complete the included mainland UK delivery and modular assembly of both wings, followed by the allocated mains connections, commissioning and handover checks before occupation.
Frequently asked questions
What are prefabricated nursery buildings?
Prefabricated nursery buildings are manufactured off site in sections for assembly at the childcare location. This L-shaped model uses the KC Bespoke construction package, with internal rooms and services agreed around the nursery brief.
What size is the L-shaped nursery building?
The building comprises a 12.60m × 6.30m wing and a 9.45m × 12.60m wing. Their gross external areas are 79.38m² and 119.07m², giving a total of 198.45m². The final floor plan defines their orientation, connection and usable internal areas.
Does the 198.45m² area count the connecting corner twice?
No. The stated total is the sum of two separate, non-overlapping rectangular wing areas. The approved plan must retain that measurement basis. The footprint is not the bounding rectangle around the complete L shape, and does not include external paths or play areas.
What is the price of this prefabricated nursery building?
The stated price is £353,245 excluding VAT, or £423,894 including the configured 20% VAT. Mainland UK delivery and on-site modular assembly are included. Groundworks, final mains connections, external works and equipment outside the agreed fit-out are separate.
Is the specification the same as the V-Design nursery?
Yes. This larger model uses the same supplied KC Bespoke material and fit-out specification as the V-Design nursery, including the 160mm roof assembly, 100mm partition panels, triple-glazed laminated windows, SPC flooring, sanitary finishes and heat pump. The L-shaped floor plan, structural connections, opening quantities and service capacities are designed separately.
Why choose an L-shaped nursery building?
Two connected wings provide a basis for separating activities or age groups while coordinating shared support facilities. The shape also offers different relationships to the site and outdoor areas. Those opportunities must be tested against supervision, circulation, usable area and the final nursery plan.
How many children can this nursery accommodate?
No fixed capacity is stated. Use the approved activity-room areas, not 198.45m² gross area. England's EYFS references 3.5m² per child under two, 2.5m² for two-year-olds and 2.3m² for ages three to five; staffing and provider requirements also apply. Check the applicable EYFS framework.
Can outdoor play space increase the indoor child-place calculation?
Not for the cited England EYFS space rules applying where indoor activity is the main or an integral part of provision. Exclusively outdoor provision is treated separately. Do not add playground area to the building footprint when assessing indoor capacity.
Can the two wings serve different age groups?
The floor plan can be developed around different age groups or activities, with suitable support rooms and supervised connections. The product does not prescribe two classrooms, separate departments or a fixed number of activity rooms.
Is this a fitted nursery specification or shell and core?
This is the fitted KC Bespoke specification, not the earlier shell-and-core pavilion offers. It includes internal partition panels, SPC flooring, scheduled doors and glazing, sanitary-area fittings and finishes, and heat-pump heating and cooling. The detailed room, electrical, lighting, ventilation, hot-water and alarm schedules must still be agreed.
Can toilets, changing, storage and staff space be included in the layout?
These requirements are developed within the approved room and sanitary schedules. Confirm the necessary child and adult facilities, handwashing, rest spaces and any food-preparation provision before setting the number of places. No kitchen appliance or loose furniture package is automatically included.
Are the windows triple glazed with laminated safety glass?
Yes. The retained specification calls for UPVC windows with triple glazing and laminated safety glass, with a specified window U-value of 0.9 W/m²K. Exact opening dimensions, quantities, restrictors and other safety details follow the approved schedule.
How are heating, cooling and ventilation specified?
Air-to-air heat-pump heating and cooling is included, with specified SCOP 4.5. Capacity, indoor units and zoning must suit the larger layout. Fresh-air ventilation, wet-area extraction, glare control and acoustics require separate design checks; no fixed equipment count is copied from the smaller nursery.
Are delivery and assembly included in the price?
Yes. Mainland UK delivery and on-site modular assembly are included in the stated £353,245 + VAT price. Confirm access, the lifting plan and foundation readiness before delivery. Groundworks, final mains connections and unspecified external works remain separate.
Are these modular nursery buildings for sale or hire?
This listing is for purchasing the stated L-shaped nursery building. No rental price, hire period or finance arrangement is offered by this configuration.
Do prefabricated nursery buildings need planning and Building Regulations approval?
Check both approval routes for the site, proposed use and location before ordering. Off-site manufacture does not itself provide an exemption. Consult government Building Regulations approval guidance and obtain advice for the relevant jurisdiction.
Is this nursery automatically Ofsted approved or A-rated?
No. Purchasing the building does not grant childcare registration or an inspection outcome. An optional A energy rating requires assessment of the final design. The applicable Part L requirements and any EPC must be confirmed for the actual project.
Do the supplied wall ratings certify the complete L-shaped nursery?
No. The supplied B-s2,d0 reaction-to-fire reference and EW 45 / EI 30 panel fire-resistance references depend on the selected system and its test conditions. The final fire strategy must address both wings, connections, escape, penetrations, doors and alarms. No whole-building REI60 rating is claimed.
How long will manufacture and installation take?
The programme is confirmed after the layout, specification, approvals and site review. The larger L-shaped building has its own manufacturing, transport and assembly plan; no lead time from another model is automatically applied.
Can work be carried out next to an operating nursery?
A live-site installation requires a plan for works segregation, safe vehicle access, delivery timing and the nursery operation. Factory manufacture reduces the work brought to site but does not remove the need to plan construction activities with the provider.
Are other cladding finishes available?
The listed standard steel cladding and flashing colours are included. Wood effects, brick slips and decorative-stone systems remain separately priced upgrades, just as in the V-Design nursery specification. Final exterior-rated products and coverage are agreed before manufacture.
Does the supplied image show everything included in the price?
No. It is an illustrative nursery setting, not a confirmed completed-project record or an equipment inventory. Furniture, toys, educational resources, fencing, planting, paths and playground items are not included unless expressly listed. The image does not establish room sizes, clear heights or door quantities.
Where can I see other nursery models or download the catalogue?
View the smaller V-Design nursery or download the KC Bespoke Collection catalogue (PDF). The price, two-wing arrangement and approved schedule on this listing apply specifically to the 198.45m² L-shaped model.
Order your L-shaped prefabricated nursery building
Send your postcode, age groups, proposed places, room requirements and target opening date. We will develop the two-wing layout and confirm services, site interfaces and the £353,245 + VAT scope, including mainland UK delivery and on-site assembly.