Home » Shop » Premium Bespoke Modular Building – 22.05m × 9.45m

Premium Bespoke Modular Building – 22.05m × 9.45m

£373,800.00+ VAT — £448,560.00 incl. VAT

Premium bespoke modular building from the KC Bespoke line, measuring 22.05m × 9.45m and providing approximately 208.37m² of gross external floor area. The 2026 specification includes an insulated steel frame, triple-glazed laminated windows, heat-pump heating and cooling, SPC flooring and an upgraded brick-slip or decorative-stone elevation finish.

Product line
KC Bespoke
External footprint
22.05m × 9.45m
Gross external area
Approx. 208.37m²
Façade upgrade
Brick-slip or decorative-stone finish included
Delivery & assembly
Included
Programme
Confirmed with the order
Product price £373,800.00 + VAT £448,560.00 incl. VAT
Order total £373,800.00 + VAT £448,560.00 incl. VAT
Availability Available to order

Delivery and on-site modular assembly are included in the stated price. The delivery postcode, access, lifting arrangements and prepared foundations must be agreed before installation. Groundworks, foundations and final connections to mains services are excluded unless separately agreed in writing.

Buy the stated specification or discuss adaptations before manufacture. The agreed drawings and order specification define the room layout, openings, façade coverage and service positions. Groundworks, foundations and final mains connections are excluded.

Available to order

KC Bespoke Collection | 2026 specification

A premium bespoke modular building with an upgraded architectural façade

This 22.05m × 9.45m bespoke modular building combines approximately 208.37m² of gross external floor area with an insulated steel-frame structure, commercial interiors and a brick-slip or decorative-stone elevation upgrade included in the price.

The KC Bespoke line allows the internal arrangement to be developed around the intended use. Office areas, meeting rooms, customer-facing accommodation and sanitary facilities are coordinated through the final floor plan rather than assumed from the overall footprint.

The supplied 2026 specification includes Kingspan insulated panels or an approved equivalent for the external walls, an insulated membrane roof, an insulated steel floor, triple-glazed UPVC windows with laminated safety glass, aluminium entrance doors, internal fire doors and air-to-air heat-pump heating and cooling.

The upgraded elevation finish is included for this product. Choose a brick-slip or decorative-stone design from the agreed range, with the exterior-rated product, colour, joint treatment and façade coverage recorded on the approved elevations. Wood-effect cladding remains a separate premium option.

Delivery and on-site assembly are included. Prepared foundations, incoming utilities and final connections to electricity, water and drainage remain site responsibilities unless separately agreed.

Explore the KC Bespoke Collection catalogue (PDF) for the wider range. The product-specific 2026 schedule and approved drawings define this building's final specification.

KC Bespoke line Approx. 208.37m² Upgraded façade included Triple-glazed safety glass Heating & cooling Delivery & assembly included
External footprint
22.05m × 9.45m
Gross external area
208.37m²
Product line
KC Bespoke
Wall U-value
Specified 0.18 W/m²K
Roof / floor U-values
Specified 0.11 / 0.11 W/m²K
Delivery & assembly
Included

Applications and layout options

Commercial workspace

Bespoke Modular Office

Develop the internal plan around workstations, private offices, meeting rooms and staff facilities. Occupancy, circulation and sanitary provision are confirmed against the brief.

Customer-facing premises

Premium Modular Commercial Building

Use the architectural façade and configurable interior for a reception building, showroom, marketing suite or other commercial premises, subject to the agreed fit-out.

Education & healthcare

Project-Specific Accommodation

The KC Bespoke system can be developed for education or healthcare projects. Specialist ventilation, acoustics, fire safety, accessibility and equipment requirements need a separate project review.

Hospitality & visitor use

Architectural Modular Space

Brick-slip or decorative-stone elevations can help the building relate to surrounding premises. Hospitality layouts, catering installations and specialist services are defined separately.

Indicative product specification

Use this table as a configuration guide. The written quotation and approved drawings control the final product, interfaces and project-specific compliance.

Bespoke modular building configuration
Product line KC Bespoke
Specification issue 2026
External dimensions 22.05m × 9.45m
Gross external floor area Approx. 208.37m², calculated from the external footprint; not net usable internal area
Module arrangement Final module division, orientation and connection details to approved drawings
Internal layout Room arrangement, occupancy, openings and sanitary quantities to the agreed floor plan
Availability Available to order
Steel structural frame
Frame High-strength closed steel profiles
Protection Anti-corrosive coating
Construction Factory-manufactured multi-module steel-frame building
Engineering Member sizes, module connections, lifting details and foundation reactions to project-specific structural design
External insulated wall panels
Panel specification Kingspan KS1000/1150 TL panels or approved equivalent
Specified U-value 0.18 W/m²K
Panel orientation Vertical or horizontal installation where supported by the selected system
Reaction-to-fire reference EN 13501-1 classification B-s2,d0, subject to the selected panel and its classification documentation
EW fire-resistance reference EW 45 (o↔i), stated span 4m, as supplied in the technical brief
EI fire-resistance reference EI 30 (o↔i), stated span 7.5m, as supplied in the technical brief
Acoustic reference 25 (-3,-5) dB, as supplied for the panel system
Performance qualification Fire and acoustic references require the matching panel test reports, thickness, orientation, span, fixings and junction details. They are not whole-building ratings.
Alternative core Mineral-wool core option available by separate specification; not the default QuadCore panel
Internal partition walls
Panel Kingspan QuadCore KS1150TL
Thickness 100 mm
Finish Double-sided white finish
Layout Partitions positioned to the approved floor plan
Room separation Additional acoustic or fire-separation requirements confirmed by the project design
Insulated roof & membrane
Insulated assembly 160 mm Kingspan QuadCore KS1150TL panels within the specified roof build-up
Specified roof U-value 0.11 W/m²K
Waterproofing Protan SE 2.0 membrane
Membrane properties UV-resistant and flame-retardant membrane with welded seams
Roof detailing Falls, outlets, perimeter details and membrane compatibility confirmed in the roof design
Solar provision Solar installation can be assessed separately for structure, fixing method and roof compatibility; panels are not included
Insulated floor & SPC finish
Structure Insulated steel floor system
Specified floor U-value 0.11 W/m²K for the complete floor build-up
Deck 18 mm cement-bonded chipboard
Floor finish SPC rigid-core vinyl flooring
Use classification Class 42 as specified
Appearance Wood or stone-effect finish selected from the agreed range
Wet-area detailing Waterproof SPC product with joints, perimeters and wet-area details installed to the flooring system requirements; this is not a claim that the whole floor assembly is waterproof
Triple-glazed windows & aluminium entrance doors
Windows Multi-chamber UPVC frames with triple glazing
Safety glazing Laminated safety glass
Specified window U-value 0.9 W/m²K
Entrance doors Aluminium doors with high-security locking
Specified entrance-door U-value 1.1 W/m²K
Door finish Customisable RAL colour
Opening schedule Window and door dimensions, quantities, positions and glass specification to approved drawings
Internal fire doors
Door rating FD30-rated internal doorsets as specified
Smoke control Smoke-control seals and compatible hardware specified within the final doorset schedule
Installation Door leaf, frame, glazing, seals and ironmongery coordinated as a complete doorset
Acoustics Required acoustic performance confirmed for the selected doorset
Sanitary areas
Toilets GEBERIT wall-hung toilets to the sanitary schedule
Vanity storage Under-sink cabinets
Wall finish Rocko Tiles panels
Panel size 2800 × 1230 × 4 mm, vertical format
Wet-area finish Waterproof, easy-clean finishes with sealed joints and penetrations
Layout & quantities WC provision, basins, accessible facilities and service positions to the approved floor plan
Heating, cooling & internal services
Climate control Air-to-air heat-pump heating and cooling
Specified SCOP 4.5; final performance depends on the selected equipment and operating conditions
System design Equipment capacity, number of indoor units and control zones matched to the layout and calculated loads
Electrical & lighting Internal electrical installation and LED lighting to the agreed service schedule
Kitchen provision Kitchen arrangement, cabinetry and appliance inclusions confirmed in the order schedule; no fixed appliance list is established by this description
Incoming services Site supply capacities, meter positions and final mains connections are outside the standard building scope
External steel elevations & standard colours
Steel cladding Hidden-fix steel elevation panels on a hot-dip galvanised substrate
Relationship to façade upgrade Steel cladding, flashings and upgraded brick-slip or stone areas coordinated on the approved elevations
Included RAL range 1015, 3000, 3009, 3011, 5010, 6029, 7016, 7024, 7035, 8004, 8017, 9002, 9006, 9007 and 9010
Other standard finish Galvanised
Colour pricing No surcharge for the listed standard steel cladding and flashing finishes
Colour confirmation Final finish selected against the agreed sample and material schedule
Brick-slip or decorative-stone elevation upgrade — included
Included upgrade An upgraded brick-slip or decorative-stone elevation finish is included in the stated product price
Selection Chosen finish, product variant, colour and extent of coverage confirmed on the approved elevations
Joint treatment Jointed or unjointed appearance where available for the selected product
Façade suitability Only products confirmed suitable for exterior use are specified externally. Decorative interior-only products are not interchangeable with façade products.
Installation design Substrate, adhesive or fixing system, movement joints, weathering details and added façade loads coordinated with the building design
Brick-slip finish selection
Nicea Nicea 1 / Nicea
Boston Boston 1 / Boston with joint
Bronx Red Bronx Red 1 on request / Bronx Red with joint
Cambridge Cambridge 13 / Cambridge
Country Country 610 / Country
Dallas Dallas 1 / Dallas with joint
Dublin Dublin 3 / Dublin with joint
Monsanto Monsanto 1 / Monsanto with joint
Rustik Rustik 540 / Rustik
Selection basis Names carried from the supplied finish range; current availability and exterior-use suitability confirmed before selection
Decorative-stone finish selection
Alzano / Amsterdam Alzano; Amsterdam
Calabria / California Calabria 1 / Calabria; California
Grenada / Jura Grenada 1 / Grenada; Jura 1 / Jura
Kenya / Lyon Kenya 1 / Kenya; Lyon 1 / Lyon
Madera / Mexicana Madera 2 / Madera; Mexicana 3 / Mexicana
Nepal / Palermo Nepal; Palermo
Roma / Sierra Roma 1 / Roma; Sierra
Timber / Toledo Timber 1 / Timber; Toledo 2 / Toledo
Selection basis The selected variant must be suitable for the intended external exposure and approved façade system
Wood-effect cladding — optional premium upgrade
Available finishes Golden Oak, Dark Walnut and Winchester
Commercial status Separately quoted premium alternative; not automatically included in addition to the brick-slip or stone elevation upgrade
Manufacturer Quality & Compliance
Important clarification Our KC Bespoke buildings are manufactured through a production partner. Any manufacturer certifications and manufacturing standards relate to the relevant manufacturer and manufacturing process, not to KC Cabins Solutions Ltd unless expressly stated otherwise.
Supporting documentation Applicable manufacturer certificates, material declarations and test reports are identified for the selected construction system
Thermal data The U-values in this listing are the values specified in the supplied 2026 brief; final component and assembly calculations must support the ordered build-up
Part L The brief references Part L 2021. The applicable edition, amendments and transitional arrangements must be confirmed for the site and approval date.
Optional A energy rating An A-rating can be set as a design objective for a separately assessed specification; no completed EPC or A-rating is claimed for this listing
Fire performance Panel reaction-to-fire classes, panel fire-resistance results and FD30 doorset ratings do not establish a whole-building fire-resistance rating
Accessibility & statutory requirements Final compliance follows the approved use, layout, fire strategy, access design and project-specific approval requirements
Delivery, assembly & programme
Delivery Included in the stated product price
On-site modular assembly Included in the stated product price
Programme Manufacture, delivery and assembly dates confirmed with the order
Site readiness Prepared foundations, safe delivery and lifting access, and agreed service interfaces required
Excluded works Groundworks, foundations and final connections to mains electricity, water and drainage unless separately agreed

Scope, responsibilities and assumptions

Included in the stated 2026 building specification

  • 22.05m × 9.45m KC Bespoke steel-frame modular building
  • Anti-corrosive treatment to the steel structural frame
  • External insulated wall panels with specified U-value 0.18 W/m²K
  • 100 mm Kingspan QuadCore KS1150TL internal partitions to the approved layout
  • Specified 160 mm insulated roof assembly and Protan SE 2.0 membrane
  • Insulated floor with 18 mm cement-bonded chipboard deck
  • SPC rigid-core vinyl flooring, specified Class 42
  • Triple-glazed UPVC windows with laminated safety glass
  • Aluminium entrance doors and FD30 internal doorsets to the opening schedule
  • GEBERIT sanitary fittings, under-sink storage and Rocko Tiles finishes to the sanitary schedule
  • Air-to-air heat-pump heating and cooling with specified SCOP 4.5
  • Internal electrical installation and LED lighting to the agreed schedule
  • Hidden-fix steel cladding and flashings where shown on the elevations
  • Listed standard RAL finishes for steel cladding and flashings
  • Brick-slip or decorative-stone elevation upgrade to the agreed finish and coverage
  • Delivery
  • On-site modular assembly

Excluded / normally client or site scope

  • Groundworks, excavations and prepared foundations or supporting base
  • Incoming electrical supply and final mains electrical connection
  • Incoming water supply and final water connection
  • External foul drainage and final waste connection
  • External surface-water drainage and site drainage connections
  • Telecommunications service and final data connection
  • Planning and statutory application fees unless expressly included
  • Site-specific access roads, parking, paths, external ramps and landscaping unless expressly included
  • Solar panels, specialist equipment and loose furniture unless listed in the order specification

Order and design assumptions

  • The intended use, site postcode and required occupancy are confirmed before manufacture
  • The approved floor plan defines module arrangement, partitions, doors, windows and sanitary provision
  • The approved elevations define the included brick-slip or stone finish and coverage
  • The selected façade system is suitable for exterior exposure and the designed support structure
  • Site access, ground conditions and lifting arrangements are reviewed before delivery
  • Foundations are ready and service capacities are confirmed before installation
  • Material substitutions require written agreement and supporting performance documentation
  • Changes from the priced specification are agreed before manufacture and may affect price and programme

The agreed order specification, signed quotation and approved drawings define the purchased building. Technical performance and project approvals must be supported by the relevant calculations, test evidence and installation records.

How the project progresses

  1. Choose the specification Purchase the listed KC Bespoke building or discuss changes to layout, openings, finishes and services before ordering.
  2. Review the site and layout Confirm the postcode, intended use, occupancy, room arrangement, foundations, access and utility requirements.
  3. Approve drawings and finishes Agree the module layout, elevations, brick-slip or stone finish, glazing, service schedules and final scope.
  4. Manufacture and fit out Manufacture proceeds after the agreed payment stage and completion of the required design approvals.
  5. Deliver and assemble Deliver the modules to the prepared site and complete the included on-site assembly. Final mains connections and site works are undertaken by the parties identified in the order.

Frequently asked questions

Which product line does this building belong to?

This is a KC Bespoke modular building with the supplied 2026 specification. It is not an MB 20K or MS-series unit.

How large is this bespoke modular building?

The external footprint is 22.05m × 9.45m. Multiplying those dimensions gives approximately 208.37m² of gross external floor area. Net usable internal area depends on the final walls, partitions and layout.

What is the 2026 price?

The stated building price is £373,800 excluding VAT, or £448,560 including 20% VAT. It includes the agreed brick-slip or decorative-stone elevation upgrade, delivery and on-site assembly.

Can I buy this specification and still request changes?

Yes. The listed building can be purchased in the stated specification. Discuss layout, opening, finish or service changes before ordering so any changes to price or programme can be agreed.

Is the brick-slip or stone façade included?

Yes. The elevation upgrade is included for this product, rather than being presented as an extra-cost upgrade. The selected exterior-rated product, finish and coverage are recorded on the approved elevations.

Are wood-effect finishes included as well?

Golden Oak, Dark Walnut and Winchester are separate premium alternatives. They are not automatically included in addition to the specified brick-slip or stone finish.

What insulation performance is specified?

The supplied 2026 schedule specifies walls at 0.18 W/m²K, roof and floor at 0.11 W/m²K, windows at 0.9 W/m²K and aluminium entrance doors at 1.1 W/m²K. The ordered components and completed assemblies require supporting performance documentation.

Are the windows triple glazed?

Yes. This product specification calls for multi-chamber UPVC windows with triple glazing and laminated safety glass. Final sizes, quantities and opening arrangements follow the approved drawings.

Does the building include heating and cooling?

Yes. Air-to-air heat-pump heating and cooling is included, with a specified SCOP of 4.5. Equipment capacity and zoning are confirmed against the layout and calculated heating and cooling loads.

Is the building automatically A-rated or certified for every use?

No. An A energy rating is an optional design objective requiring assessment of the final building. The applicable Part L requirements also depend on the project. See the Approved Document L guidance for England and Building Regulations approval guidance.

Do the panel fire ratings apply to the whole building?

No. The listed B-s2,d0, EW 45 and EI 30 references concern the selected panel system and its documented test conditions. Internal doors are specified as FD30 doorsets. The final building fire strategy must address the complete construction, junctions, penetrations and escape arrangements.

What must be prepared before delivery?

The site requires suitable foundations, safe vehicle and lifting access and agreed utility interfaces. Groundworks, foundations and final mains connections are excluded unless separately agreed.

What is the manufacturing lead time?

The programme is confirmed with the order after the layout, material selections, approvals and site requirements are agreed. A fixed lead time has not been established for this particular configuration.

Can this be used as a bespoke modular office or another commercial building?

The layout can be developed for office or other commercial uses. Education, healthcare, hospitality and specialist uses require their own review of occupancy, fire safety, accessibility, acoustics, ventilation and equipment.

Where can I see the catalogue?

Download the KC Bespoke Collection catalogue (PDF). It introduces the wider range; the agreed 2026 product schedule defines this building.

Buy this KC Bespoke building or discuss your project specification

Send your site postcode, intended use, room requirements, preferred brick-slip or stone finish and target installation date. The team will confirm the layout, included façade treatment, access arrangements and programme before manufacture.